Document: 66APPMAN-PC Rev: C 18 of 28
10.7 STANDALONE TEST MODES
Test modes are specified by address location and may be used to
debug network connections or provide standalone color changing
options without the need for a DMX controller. Colours are assuming
LED loads are connected in RGB configuration as shown on page 15,
section 9.4)
ADDRESS FUNCTION/SEQUENCE
000 NO FUNCTION
001-512 DMX ADDRESS MODE
513 GREEN ON
514 RED ON
515 BLUE ON
516 BLUE & RED ON (MAGENTA)
517 BLUE & GREEN ON (CYAN)
518 GREEN & RED ON (YELLOW)
519 ALL OUTPUTS AT 5%
520 EACH COLOR RAMPING UP AND DOWN INDIVIDUALLY SPEED 1
521 EACH COLOR RAMPING UP AND DOWN INDIVIDUALLY SPEED 2
522 CROSS FADE BETWEEN COLOURS (RED UP, GREEN UP, RED
DOWN, BLUE UP ETC.) SPEED 1
523 CROSS FADE BETWEEN COLOURS (RED UP, GREEN UP, RED
DOWN, BLUE UP ETC.) SPEED 2
524 CROSS FADE BETWEEN COLOURS (RED UP, GREEN UP, RED
DOWN, BLUE UP ETC.) SPEED 3
525 CROSS FADE BETWEEN COLOURS (RED UP, GREEN UP, RED
DOWN, BLUE UP ETC.) SPEED 4
526 CROSS FADE BETWEEN COLOURS (RED UP, GREEN UP, RED
DOWN, BLUE UP ETC.) SPEED 5
530 ALL ON
531 CHANNEL 1 ON
532 CHANNEL 2 ON
533 CHANNEL 3 ON
534 CHANNEL 4 ON
535 CHANNEL 5 ON
536 CHANNEL 6 ON
537 CHANNEL 7 ON
538 CHANNEL 8 ON
539 CHANNEL 9 ON
540 CHANNEL 10 ON
541 CHANNEL 11 ON
542 CHANNEL 12 ON
Document: 66APPMAN-PC Rev: C
11 of 28
8.0 OUTPUT CHANNEL REQUIREMENTS
8.1 Electrical Output Specifications:
Output specifications are defined in table 2 on page 4 of this manual.
Actual output currents and maximum voltages are dependant on the
model configuration, see table 6, 8 or table 10 at the beginning of this
manual for configuration options.
8.2 Output Wiring Requirements
WARNING: All output channels are isolated from each other and
require a separate 2 wire twisted pair for each output LED load.
When connecting LED loads to output cables observe ‘+’ and ‘-‘ po-
larity connections to prevent damage to loads. To reduce risk of fire or
electric shock, do not interconnect output terminations.
A common anode or cathode wiring method for multiple LED
loads cannot be used for the TRINITY PC.
All output wires should be connected to their respective LED loads
before power up to prevent inadvertent shorting of outputs. Shorting of
outputs (+ve to ve only) will result in a hiccup mode of operation with
automatic recovery after removal of a short.
Output Class 2 circuit wiring must comply with NEC Article 725 wir-
ing methods or to CEC section 16-210 wiring methods.
Output cabling should be overall shielded cables with twisted pair
conductors (18 AWG ) to minimize cross talk between channels and mini-
mize Electromagnetic Interference (EMI).
Consult your local Electrical Safety Authority for acceptability in
your end use application.
With appropriate cabling, the TRINITY PC may be remote mounted
up to 150 feet (45 meters) from the LED loads.
7.0 INPUT REQUIREMENTS
7.1 Electrical Input Specifications:
Input specifications are defined in table 1 on page 4 of this
CAUTION
RISK OF DAMAGE:
DO NOT connect input of power unit to a phase cut dimmer or dim-
ming panel. It will cause internal damage to the power unit