Document: 66APPMAN-PC Rev: C
19 of 28
10.8 MULTI CHANNEL CONTROL MODES
The Trinity PC is able to link certain output channels together so that
they will respond on the same DMX channel. This is useful for general
illumination applications, For example all the lighting in a room could
be connected to a single Trinity PC, and all lights can be dimmed by a
single DMX channel. See table below for mapping.
ADDRESS FUNCTION/SEQUENCE (For a 9 & 12 Channel Unit)
601 DMX ADDRESS 1 CONTROLS CHANNELS 1,2 & 3; DMX ADDRESS 2
CONTROLS CHANNELS 4,5, & 6; DMX ADDRESS 3 CONTROLS
CHANNELS 7,8, & 9; DMX ADDRESS 4 CONTROLS CHANNELS 10, 11,
& 12
602 DMX ADDRESS 2 CONTROLS CHANNELS 1,2 & 3; DMX ADDRESS 3
CONTROLS CHANNELS 4,5, & 6; DMX ADDRESS 4 CONTROLS
CHANNELS 7,8, & 9; DMX ADDRESS 5 CONTROLS CHANNELS 10, 11,
& 12
… …
699 DMX ADDRESS 99 CONTROLS CHANNELS 1,2 & 3; DMX ADDRESS
100 CONTROLS CHANNELS 4,5, & 6; DMX ADDRESS 101 CONTROLS
CHANNELS 7,8, & 9; DMX ADDRESS 103 CONTROLS CHANNELS 10,
11, & 12
700 CHANNELS 1 TO 6 ON DMX ADDRESS 1, CHANNELS 7 TO 12 ON
DMX ADDRESS 2
701 CHANNELS 1 TO 6 ON DMX ADDRESS 2, CHANNELS 7 TO 12 ON
DMX ADDRESS 3
… …
799 CHANNELS 1 TO 6 ON DMX ADDRESS 99, CHANNELS 7 TO 12 ON
DMX ADDRESS 800
801 ALL CHANNELS ON DMX ADDRESS 1
802 ALL CHANNELS ON DMX ADDRESS 2
… …
850 ALL CHANNELS ON DMX ADDRESS 50
ADDRESS FUNCTION/SEQUENCE (For a 6 Channel Unit)
601 DMX ADDRESS 1 CONTROLS CHANNELS 1 & 2; DMX ADDRESS 2
CONTROLS CHANNELS 3 & 4; DMX ADDRESS 3 CONTROLS
CHANNELS 5 & 6;
602 DMX ADDRESS 2 CONTROLS CHANNELS 1 & 2; DMX ADDRESS 3
CONTROLS CHANNELS 3 & 4; DMX ADDRESS 4 CONTROLS
CHANNELS 5 & 6;
… …
699 DMX ADDRESS 99 CONTROLS CHANNELS 1 & 2; DMX ADDRESS 100
CONTROLS CHANNELS 3 & 4; DMX ADDRESS 101 CONTROLS
CHANNELS 5 & 6;
700 CHANNELS 1 TO 3 ON DMX ADDRESS 1, CHANNELS 4 TO 6 ON DMX
ADDRESS 2
701 CHANNELS 1 TO 3 ON DMX ADDRESS 2, CHANNELS 4 TO 6 ON
DMX ADDRESS 3
… …
799 CHANNELS 1 TO 3 ON DMX ADDRESS 99, CHANNELS 4 TO 6 ON
DMX ADDRESS 800
801 to 850 SAME AS 9 & 12 CHANNEL TABLE ABOVE